35kv high voltage Overhead Cable XLPE insulated

35kv high voltage Overhead Cable XLPE insulated
Product Detailed
Related Categories:Power Cables
aluninum stranded wire XLPE insulated overhead cable voltage:35 kv standard:BS,ICEA,NFC OEM order taken

 JKLYJ-30KV-1×150

1.Standars

a.TheAerial Insulated Cable meets the China’s standard of GB/T14049-2008

b.Internationalstandard also can be satisfied because we are manufactures.

c.Andcustomer special request can be fulfilled too.

2.Applications

a.CopperConductor or Aluminum Conductor with XLPE or HDPE insulation Aerial Cable issuiltable for aerial power lines withA.C. rated voltage U/Um up to 10/12kv and 35/42kv

b.Thesoft copper conductor cable is used as lead of transformer.A certain distanceshould be kept between cable and trees during installation. Frequently touchingbetween cables and trees is allowed during operation.

b.Only short time touching Allowed during operation for light duty type JKLY/Q,JKLGY/Q,JKLYJ/Q,JKLGJ/Q.(Light Duty Type)

3.Classificationof products

4.Specification

Type

No. of Cores

Rated Voltage

10 kv

35 kv

Nominal Cross-section Area mm²

JKLYJ JKTRYJ JKLGYJ

1,3

35~300

50~300

JKTRY

1

35~300

 

JKLY JKLGY

JKLY/Q,JKLGY/Q

JKLYJ/Q,JKLGJ/Q

1

10~300

 

5.UsingProperties

a.RatedVolatge:35KV

b.Cable installation temperature not less than -20°C

c.Max.temperature of cable at short circuit(The max. duration does not exceed 5minutes)

   For XLPE insulation is 250°C.

   For HDPE insulation is 150 °C.

d.TheMax. bending radius of cable shall not be less than 20(D+d)mm(D and d representthe nominal overall diameter of cable and diameter of conductor )

6.TechnicalSpecification

JKLYJ 35KV     

Cross-section Area

mm²

Thickness of Insulation

mm

Approx. Overall Dia.

mm

Max. Resistance of Conductor at 20 °C

Ω/km

Min. Breaking Load of conductor

N

Approx. Weight of Cable

kg/km

      
509.328.50.6417011726.4
709.330.20.44310354831.4
959.331.80.32013727953.1
1209.333.20.253173391067.2
1509.334.80.206210331199.6
1859.336.40.164267321344.9
2409.338.60.125346791559.2
3009.340.30.100433491791.5

35kv high voltage Overhead Cable XLPE insulated